Rebuild rack01 from the physically remounted hardware: - Correct stale positions/ports/outlets for pp01, pp02, sw01, pdu01-04 - Model shelves as 1U trays (towers stand above without consuming rack U's); add shf02 and empty half-depth shf03/shf04 - Add ups01/ups02; reseat nas01/02 and sw02-05; move srv04-07 onto shf02 - Add `wan` hardware kind; add WAN demarcation hosts wan01 (active) and wan02 (staging) - Document full live network wiring: srv01-07 -> pp02 -> sw01 (LAN) and srv01 eth0 -> pp02 -> pp01 -> wan01 (WAN); keep non-active lines (wan2, working-table patches, sw01 mgmt) in notes only - Regenerate hardware index + rack01 elevation/network/power artifacts Also includes the in-progress generator updates (gen_rack.py, gen_overview.py, Makefile, tests) that the regenerated artifacts depend on. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
17 lines
375 B
Markdown
17 lines
375 B
Markdown
---
|
||
hostname: sw01
|
||
kind: switch
|
||
status: in-use
|
||
rack: rack01
|
||
rack_u: 23
|
||
u_height: 1
|
||
rack_face: front
|
||
ports: 10
|
||
---
|
||
|
||
## Notes
|
||
|
||
- 10 ports: p1–p8 are 1 GbE; sfp1–sfp2 are 2.5 GbE SFP+ (unused today).
|
||
- p1–p7 carry server uplinks via pp02 (pp02:2–8 → sw01:1–7).
|
||
- p8 is the management port, patched out via pp01:4 to the working table
|
||
(black cable) — non-active.
|