# CRS310 — flat data path + isolated management VLAN — Design
|
|||
|
|
|
|||
|
|
**Date:** 2026-06-09
|
|||
|
|
**Status:** Approved (brainstorming complete)
|
|||
|
|
**Author:** sjat + Claude
|
|||
|
|
**Supersedes** the placeholder topology in `host_vars/crs310-maker.yml` (the
|
|||
|
|
`10.0.99.x` / SFP+-trunk example). Builds on
|
|||
|
|
`2026-06-07-mikrotik-crs310-ansible-design.md`.
|
|||
|
|
|
|||
|
|
## Purpose
|
|||
|
|
|
|||
|
|
Bring the makerspace CRS310 into service as a **flat L2 switch** on the existing
|
|||
|
|
`10.2.30.0/24` network, with its **management plane isolated on a dedicated VLAN**
|
|||
|
|
reached through one physical port. No SFP+ yet — the 10G uplink is deferred until the
|
|||
|
|
connectors arrive; **`ether1` is the (copper) uplink** for now.
|
|||
|
|
|
|||
|
|
## Context (as found on 2026-06-09)
|
|||
|
|
|
|||
|
|
- Switch on factory **defconf**: one flat `bridge` with all ports, mgmt IP
|
|||
|
|
`192.168.88.1/24` sitting directly on `bridge`, `vlan-filtering=no`.
|
|||
|
|
- Upstream LAN is **flat**: DHCP/gateway at `10.2.30.1`, untagged. Verified by leasing
|
|||
|
|
`10.2.30.227` to mamba *through* the switch's flat bridge.
|
|||
|
|
- mamba is the management station (patched into the switch, reached from fisi over a
|
|||
|
|
`kuku` jump + port-forward tunnel to `192.168.88.1`).
|
|||
|
|
|
|||
|
|
## Topology
|
|||
|
|
|
|||
|
|
VLAN-aware bridge (`bridge`), `vlan-filtering=yes` enabled **last**. All ports are
|
|||
|
|
untagged access ports — **no trunks**.
|
|||
|
|
|
|||
|
|
| Port | Mode | PVID | VLAN | Notes |
|
|||
|
|
|---|---|---|---|---|
|
|||
|
|
| `ether1` | access | 30 | DATA | copper uplink to `10.2.30.0/24` |
|
|||
|
|
| `ether2`–`ether7` | access | 30 | DATA | device access ports |
|
|||
|
|
| `sfp-sfpplus1/2` | access | 30 | DATA | unused until connectors arrive |
|
|||
|
|
| `ether8` | access | 99 | MGMT | dedicated management port (mamba lives here) |
|
|||
|
|
|
|||
|
|
- **DATA VLAN 30** — internal-only id; ingress/egress on `ether1` is untagged, so the
|
|||
|
|
upstream router sees a plain flat network. The switch CPU (`bridge`) is **not** a
|
|||
|
|
member of VLAN 30 → no switch L3 presence on the user network.
|
|||
|
|
- **MGMT VLAN 99** — `vlan-mgmt` interface on the bridge, IP **`192.168.88.1/24`**, the
|
|||
|
|
bridge/CPU is the only tagged member, `ether8` the only untagged member.
|
|||
|
|
**No default gateway** — management is intentionally isolated.
|
|||
|
|
|
|||
|
|
## Management & internet
|
|||
|
|
|
|||
|
|
- Reachable only from `ether8` (plug the management laptop / mamba there, addressed
|
|||
|
|
`192.168.88.2/24`). The switch does **no routing or DHCP**; `10.2.30.1` keeps both.
|
|||
|
|
- The control plane has **no internet** by design → **NTP/DNS disabled** (they would
|
|||
|
|
only error on an isolated segment; clock won't sync, updates are done manually when
|
|||
|
|
the switch is temporarily patched to the data network).
|
|||
|
|
|
|||
|
|
## Required changes to the IaC
|
|||
|
|
|
|||
|
|
1. `host_vars/crs310-maker.yml`: replace the placeholder topology with the table above;
|
|||
|
|
`switch_mgmt_address: 192.168.88.1/24`, `switch_mgmt_vlan_id: 99`, **no gateway**;
|
|||
|
|
drop the `10.0.99.x` DNS/NTP/gateway placeholders.
|
|||
|
|
2. Role `vlans.yml`: make the **default-route** task conditional on a gateway being set
|
|||
|
|
(skip when isolated); **remove the legacy defconf IP** off the bare `bridge` so it
|
|||
|
|
doesn't collide with the `vlan-mgmt` IP (`192.168.88.1` must live only on
|
|||
|
|
`vlan-mgmt`).
|
|||
|
|
3. Role `identity.yml`: gate NTP (and DNS) behind a flag / empty-server check so an
|
|||
|
|
isolated mgmt plane doesn't configure unreachable servers. Add
|
|||
|
|
`switch_ntp_enabled: false` for this host.
|
|||
|
|
|
|||
|
|
The existing `vlans.yml` membership Jinja already produces the correct sets for an
|
|||
|
|
all-access topology (DATA untagged = data ports, CPU tagged only on MGMT).
|
|||
|
|
|
|||
|
|
## Cutover runbook (lockout-safe; operator on-site at `ether8`)
|
|||
|
|
|
|||
|
|
1. **Restore mgmt path** (done): mamba `enp0s31f6` → `192.168.88.2/24` (profile
|
|||
|
|
`crs310-bench`); fisi→mamba→switch tunnel up; Ansible reaches `192.168.88.1`.
|
|||
|
|
2. **Move the cable: switch port 5 → port 8.** (Bridge is still flat, so mamba stays
|
|||
|
|
reachable on either port.) Re-confirm reachability.
|
|||
|
|
3. Apply config in order: bridge VLAN table → port PVIDs → create `vlan-mgmt` iface.
|
|||
|
|
Verify the VLAN/PVID state with `vlan-filtering` still **off**. Then the **flip**, as
|
|||
|
|
one ordered sequence (the address can't be on both interfaces at once): remove
|
|||
|
|
`192.168.88.1` from `bridge`, add it to `vlan-mgmt`, set `vlan-filtering=yes`. mamba
|
|||
|
|
(`ether8`, untagged VLAN 99, `.2`) ↔ switch (`.1`) is the canary; the SSH/tunnel may
|
|||
|
|
blip during the flip but must come back. Pre-verifying PVID/membership before the
|
|||
|
|
flip is what prevents a hard lockout.
|
|||
|
|
4. Verify: `/interface/bridge/vlan/print` membership correct, mgmt still reachable, a
|
|||
|
|
device on `ether1`-fed ports still gets `10.2.30.x`.
|
|||
|
|
|
|||
|
|
## Risks
|
|||
|
|
|
|||
|
|
- **Lockout** on enabling `vlan-filtering` if `ether8`/VLAN 99/mgmt-IP aren't aligned.
|
|||
|
|
Mitigated by ordering (filtering last), the live canary connection, and the operator
|
|||
|
|
being on-site to re-cable. WinBox-MAC recovery is unavailable (broken under Wine);
|
|||
|
|
worst case is a no-defaults reset, which we avoid.
|
|||
|
|
- **Removing the legacy bridge IP** is the delicate step — done while the new
|
|||
|
|
`vlan-mgmt` IP is the same address, before filtering, with the connection watched.
|
|||
|
|
|
|||
|
|
## Out of scope
|
|||
|
|
|
|||
|
|
Real inter-VLAN segmentation, the SFP+ 10G uplink/trunk, and any upstream router VLAN
|
|||
|
|
work — revisited when the connectors and a real VLAN plan are ready.
|